Brain-Computer Interfaces and Neurotechnology for Spinal Cord Injury: What the SCI Community Should Know

A plain-language look at brain-computer interfaces, the neural bypass, brain-spine interfaces, and spinal cord stimulation after SCI: how each works, what is investigational, what is available, and Ian Burkhart's story.

A brain-computer interface (BCI), often called a brain implant in everyday speech, reads signals from the brain and turns them into action outside the body. After a spinal cord injury (SCI), that action can be a cursor on a screen, a robotic arm, a spinal stimulator, or the person's own hand. Most of what this article describes is investigational, meaning it is available only inside a clinical trial. One system, an external spinal cord stimulator used in the clinic, received marketing authorization from the US Food and Drug Administration (FDA) for incomplete cervical SCI in December 2024 [1]. The rest of the field is measured in single participants and small groups, and the article says so at every point where it matters.

What Neurotechnology Means After Spinal Cord Injury

Between 1998 and 2023, twenty-one research groups worldwide conducted twenty-eight clinical trials of implanted brain-computer interfaces, with sixty-seven participants in total [2]. That is the whole human record of the implanted side of this field over twenty-five years. It is small, it is slow, and the results inside it are real. Understanding what these devices do, and what they do not do, starts with what an injury to the spinal cord takes away.

How a Spinal Cord Injury Interrupts the Signal Between Brain and Body

The spinal cord carries commands down from the brain to the muscles and carries touch, temperature, and position back up. An injury damages that two-way traffic at one level, and the effect depends on how much of the cord at that level still works. In a motor complete injury, there is no voluntary movement or sphincter control below the level of injury, though some sensation may remain. A fully complete injury also leaves no sensation, down to the lowest segments of the cord [3]. An incomplete injury leaves some signal crossing the damaged segment. Since 2015, incomplete , also called quadriplegia, has been the most common category in the National Spinal Cord Injury Statistical Center database, which draws on the US Spinal Cord Injury Model Systems, at 47.6 percent of new injuries, and complete tetraplegia the least common of the four injury categories, at 12.1 percent [4]. Fewer than 1 percent of people recover completely by hospital discharge [4].

Think of the wiring in a house. A light switch on one wall, a lamp on the other, and a wire between them inside the wall. Cut that wire and the switch still clicks. The lamp still works if you plug it in somewhere else. The two have only lost the connection that let one control the other. In this picture the brain is the switch that initiates movement, the lamp is the muscle that moves the limb, and the cut wire is the injured segment of the spinal cord. Every technology in this article is a different way of dealing with a cut wire, and the picture returns throughout the piece.

Two facts, one on each side of the injury, shape everything that follows. First, the switch keeps working. The motor cortex is the part of the brain that plans and initiates movement, and three years after a cervical injury, intended hand movement still produced clear patterns of firing there in the first BrainGate participant, which is what made decoding possible [5]. Second, the circuits below the cut are alive. At the University of Louisville, epidural stimulation of the lumbosacral cord produced intentional leg movement in four of four participants who had been classified as having complete paralysis, two of whom were both motor and sensory complete [6]. Mayo Clinic researchers describe these spinal networks as functionally disconnected from the brain, and say they can be facilitated with stimulation [7]. A Battelle team went further and showed that faint touch signals from a hand still reach the brain through a clinically complete injury at a level below conscious awareness, and a device can pick them up [8]. The wire is damaged. It is rarely gone.

If the terms above are new, the North American Spinal Cord Injury Consortium (NASCIC) hub articles on what a spinal cord injury is and the American Spinal Injury Association (ASIA) Impairment Scale explain level and completeness in full. What matters here is that a working switch and a living lamp are the two conditions a brain-computer interface needs.

What a Brain-Computer Interface Is (and What It Is Not)

The FDA defines implanted BCI devices as neuroprostheses that interface with the central or peripheral nervous system to restore lost motor or sensory capabilities in people with paralysis or amputation [9]. A review published in 2024 and co-authored by NASCIC past President Ian Burkhart puts it in research terms: an implanted BCI translates brain activity recorded inside the skull into commands for virtual or physical machines, to restore or rehabilitate motor, sensory, or speech function [2]. Strip both definitions down and a BCI is a device that listens to the brain and acts on what it hears.

It is not mind reading. Intracortical arrays like BrainGate's record electrical activity from a patch of motor cortex about 4 millimeters on a side, an area that fires when a person tries to move [5][10]. They do not read thoughts, memories, or feelings. They read intention to move, and only after weeks of training in which the person and the software learn each other. Nor is it a cure. Every result reported in this article happened with the device in place and switched on, and the sections on realistic expectations and on Ian Burkhart's experience return to what that means when a device comes out.

The phrase also hides how different the devices are. Some BCIs record from arrays of tiny needles pressed into the cortex, the intracortical approach used in the BrainGate studies [5]. Some record from a thin film laid on the brain's surface [11]. One sits inside a blood vessel next to the motor cortex rather than in the brain itself [12]. And the closely related brain-spine interface does not send the brain's signal to a machine at all. It sends it to a stimulator on the spinal cord below the injury [13]. The word "brain implant" covers all of these in conversation, which is why the sections that follow name each one and say what it does.

The record behind these devices is longer than most people assume and smaller than the headlines suggest. Twenty-five years of trials, four types of electrode array, 165 peer-reviewed papers, and, as of that review, no implanted BCI approved by any regulator for sale as a medical device [2]. The average time from a participant's implant surgery to the first published paper is three years [2]. The next section opens the device up and shows what happens in between.

Brain computer interface diagram: one sensor, one decoder, three destinations

Every brain-computer interface reads intention to move from the motor cortex, decodes it in software, and sends the command to an effector. Which effector it reaches is what separates a robotic arm from a neural bypass from a brain-spine interface.

1 2 3 1 Sensor An electrode array on orin the motor cortexrecords the firingpattern that an attemptedmovement produces. 2 Decoder Software trained on weeksof attempts translates thepattern into a command:open, close, reach, or aletter. 3 Effector External device Cursor, keyboard, orrobotic arm. The BrainGateroute since 2006. Own muscles (neural bypass) A stimulation sleeve on theforearm moves the person'sown hand. Battelle and OhioState, 2014. Spinal cord (brain-spine interface) Epidural stimulation belowthe injury, shaped in realtime by the decoded intent.Lausanne, Switzerland,2023. Implanted, inside the body Worn or outside the body The injury 1 2 3 1 Sensor An electrode arrayon or in the motorcortex records thefiring pattern that anattempted movementproduces. 2 Decoder Software trained onweeks of attemptstranslates the patterninto a command: open,close, reach, or aletter. 3 Effector External device Cursor, keyboard, orrobotic arm. The BrainGateroute since 2006. Own muscles (neural bypass) A stimulation sleeve on theforearm moves the person'sown hand. Battelle and OhioState, 2014. Spinal cord (brain-spine interface) Epidural stimulation belowthe injury, shaped in realtime by the decoded intent.Lausanne, Switzerland,2023. Implanted, inside the body Worn or outside the body The injury 1 2 3 Externaldevice Ownmuscles Spinalcord
  1. 1Sensor. An electrode array on or in the motor cortex records the firing pattern that an attempted movement produces.
  2. 2Decoder. Software trained on weeks of attempts translates the pattern into a command: open, close, reach, or a letter.
  3. 3Effector. External device: cursor, keyboard, or robotic arm. The BrainGate route since 2006. Own muscles (neural bypass): a stimulation sleeve on the forearm moves the person's own hand. Battelle and Ohio State, 2014. Spinal cord (brain-spine interface): epidural stimulation below the injury, shaped in real time by the decoded intent. Lausanne, Switzerland, 2023.
  • Implanted, inside the body
  • Worn or outside the body
  • The injury
  1. 1. Sensor. An electrode array on or in the motor cortex records the firing pattern that an attempted movement produces.
  2. 2. Decoder. Software trained on weeks of attempts translates the pattern into a command: open, close, reach, or a letter.
  3. 3. Effector, external device. Cursor, keyboard, or robotic arm. The BrainGate route since 2006.
  4. 3. Effector, own muscles (neural bypass). A stimulation sleeve on the forearm moves the person's own hand. Battelle and Ohio State, 2014.
  5. 3. Effector, spinal cord (brain-spine interface). Epidural stimulation below the injury, shaped in real time by the decoded intent. Lausanne, Switzerland, 2023.

Components as listed in Colachis SC 4th, et al. Front Neurosci. 2018 [14]; effector examples from Hochberg LR, et al. Nature. 2006 [5], Bouton CE, et al. Nature. 2016 [15], and Lorach H, et al. Nature. 2023 [13].

How a Brain-Computer Interface Works: Sensor, Decoder, Effector

Every BCI has three parts, and a 2018 paper from the Battelle and Ohio State team that worked with Ian Burkhart lists them plainly. First, a Utah microelectrode array implanted in the hand region of the motor cortex, connected to a data acquisition system. Second, a computer using a machine learning algorithm that decodes the user's intended movement from the neural activity. Third, a stimulation system with up to 130 electrodes wrapped around the forearm to move the hand [14]. Sensor, decoder, effector. Change any one of the three and you have a different device.

The sensor is where the physical differences between devices live. The Utah array is a square of 96 tiny electrodes, about the size of a baby aspirin, placed on the motor cortex so the electrode tips sit among the neurons [5][16]. The first BrainGate participant received one in 2004, and the same array design was still in use in the trial's 2023 safety report [17]. Other sensors trade depth for safety: an electrode array that rests on the brain's surface [11], or a stent lined with electrodes placed in a vein that lies alongside the motor cortex [12]. The tradeoff is real. Needles in the cortex record individual neurons and give the richest signal. A stent in a vein records from farther away and gives less, with no open-brain surgery.

The decoder is software, and it is where the weeks of training go. Think of the voice-to-text feature on a phone. Out of the box it makes mistakes; after it has heard your voice for a while it stops making them. A decoder learns the same way, except that the person cannot speak the training data aloud. They attempt a movement, over and over, while the array records the pattern that attempt produces. Stanford's handwriting BCI was trained on a participant attempting to write letters by hand, and it reached ninety characters per minute with 94.1 percent raw accuracy [18]. Battelle's team spent seven months with Ian Burkhart and collected about 300 hours of recorded data to build his decoder [19].

The effector is whatever the decoded command controls. In the house-wiring picture, it is where the new wire ends. Wire it to a cursor or a robotic arm and the switch now controls something that was never in the house [10]. Wire it to electrodes on the person's own forearm and the switch controls the original lamp again, which is what the Battelle team meant by an electronic neural bypass [15]. Wire it to a stimulator on the spinal cord below the injury and the switch talks to a second switchbox that still controls its own lamps, which is the brain-spine interface [13]. Same sensor, same kind of decoder, three different destinations.

Restoring Movement or Restoring Communication: Two Different Goals

The field splits along the effector. One branch aims at movement, the other at communication, and the two have moved at different speeds.

The movement branch began with a cursor. In 2006, the first BrainGate participant, a man three years past a cervical injury, opened simulated email and operated a television with a neural cursor, and opened and closed a prosthetic hand by neural control, all decoded from a 96-electrode array [5]. Six years later, two people with chronic tetraplegia from brainstem stroke used the same kind of array to control a robotic arm in three dimensions, and one of them, implanted five years earlier, used it to drink coffee from a bottle [10]. Hochberg and colleagues noted that the robotic reach and grasp actions were slower and less accurate than an able-bodied person's, and said so in the abstract [10]. Then the branch turned inward. In work published in 2016 by Battelle and Ohio State, and in 2017 by Case Western Reserve University, the effector became the participant's own arm, through surface electrodes in the first case and fine-wire electrodes placed in the arm muscles through the skin in the second [15][14][20].

The communication branch has moved faster, in part because a cursor or a keyboard is an easier effector than a limb. Stanford's handwriting decoder reached typing speeds comparable to smartphone typing for the participant's age group [18]. Speech decoders followed. In 2023 a Stanford team decoded attempted speech at sixty-two words per minute in a participant with amyotrophic lateral sclerosis (ALS), and in 2024 a UC Davis team reported 97.5 percent accuracy sustained over eight months in another participant with ALS, again using intracortical arrays [21][22]. Both are important results for people who cannot speak. Neither participant had a spinal cord injury, and this article labels non-SCI results wherever they appear.

Which branch matters more depends on who you ask, and the people most affected have answered. Inanici and colleagues at the University of Washington, citing a 2004 survey of people with SCI, wrote that regaining control of hand and arm movement is the highest treatment priority for people with paralysis, six times higher than restoring walking [23]. That single finding explains why so much of the SCI work in this article aims at the hand, and why the next section's vocabulary matters: the words tell you which branch, and which effector, a given device belongs to.

Two goals, measured two ways: what movement and communication BCIs have reported

Movement results are reported as tasks completed with a device on. Communication results are reported as speed and accuracy. Each card names the number of participants behind it.

  • nParticipants with SCI or brainstem stroke
  • nParticipants with ALS, not SCI
Restoring movement
  • 2006 Neural cursor opened email and operated a television; a prosthetic hand opened and closed1 participant, SCI. Massachusetts General Hospital and Brown [5]
  • 2012 Robotic arm reach and grasp in three dimensions; one participant drank coffee from a bottle2 participants, brainstem stroke. BrainGate [10]
  • 2016 Own hand: six wrist and hand motions; grasp, manipulate, and release objects1 participant, C5 SCI. Battelle and Ohio State [15]
  • 2017 Own arm through implanted stimulation: drank from a mug 11 of 12 tries; fed himself1 participant, C4 SCI. Case Western and the Cleveland Veterans Affairs (VA) Medical Center [20]
Restoring communication
  • 2021 Handwriting decoded to text at 90 characters per minute, 94.1 percent raw accuracy1 participant, SCI. Stanford [18]
  • 2021 Endovascular Stentrode: typing with click accuracy above 92 percent, used at home2 participants, ALS (not SCI). Melbourne and Synchron [12]
  • 2023 Attempted speech decoded at 62 words per minute; 23.8 percent word error on a 125,000-word vocabulary1 participant, ALS (not SCI). Stanford [21]
  • 2024 97.5 percent accuracy sustained over 8.4 months, about 32 words per minute1 participant, ALS (not SCI). UC Davis [22]
Data behind the figure
YearGoalResultParticipantsSource
2006MovementNeural cursor; prosthetic hand open and close1, SCIHochberg 2006 [5]
2012MovementRobotic arm reach and grasp; drinking from a bottle2, brainstem strokeHochberg 2012 [10]
2016MovementOwn hand, six motions1, SCIBouton 2016 [15]
2017MovementOwn arm, reach and grasp with implanted muscle stimulation1, SCIAjiboye 2017 [20]
2021Communication90 characters per minute, 94.1 percent1, SCIWillett 2021 [18]
2023Communication62 words per minute1, ALSWillett 2023 [21]
2024Communication97.5 percent over 8.4 months1, ALSCard 2024 [22]
2021CommunicationClick accuracy above 92 percent, home use2, ALSOxley 2021 [12]
2021PriorityHand and arm control 6x higher priority than walkingCited survey (Anderson 2004)Inanici 2021 [23]

The Vocabulary: Neuroprosthetic, Neuromodulation, Neural Bypass, Brain-Spine Interface

Five terms cover nearly everything a reader will meet in a news story or a trial listing, and each one points at a specific place in the sensor-decoder-effector chain.

A neuroprosthetic (or neuroprosthesis) is the broadest word. In its BCI guidance, the FDA describes implanted BCI devices as neuroprostheses that interface with the central or peripheral nervous system to restore lost motor or sensory capabilities in people with paralysis or amputation [9]. Hunter Peckham and Jayme Knutson at Case Western, where the Freehand hand system for SCI was developed before a local company brought it to market in 1997 [24], use it for stimulation systems that restore function in the arm, leg, bladder, bowel, and breathing, some of which became products and some of which stayed in research [25]. A cochlear implant is a neuroprosthetic. So is every device in this article.

Brain-machine interface (BMI) and brain-computer interface mean the same thing. Duke University's Miguel Nicolelis and Mikhail Lebedev, who use the first term, define it as a real-time, two-way link between a living brain and an artificial actuator, and date the field's serious start to the end of the 1990s [26]. Most US clinical work uses "brain-computer interface." The search engines treat the terms as synonyms, and so does this article.

Neuromodulation means changing how a nerve circuit behaves by stimulating it, without recording from the brain at all. Epidural and transcutaneous spinal cord stimulation are neuromodulation. In the house-wiring picture, neuromodulation turns up the voltage below the cut so that whatever faint signal still crosses the damaged wire is enough to light the lamp. Harkema and colleagues described it as putting the spinal circuitry into a physiological state where sensory input can serve as a source of control [27].

A neural bypass is Battelle's term for a BCI whose effector is the person's own muscles, an electronic route around the disconnected pathway [15]. The new wire goes from the switch to the original lamp.

A brain-spine interface, or digital bridge, is a BCI whose effector is a stimulator on the spinal cord itself. The brain's decoded intent adjusts the stimulation in real time, so the circuits below the injury receive a command shaped by what the person is trying to do [13].

With the vocabulary in place, the main types can be laid out one at a time, from the most invasive to the least, with the US regulatory status of each as of September 2026.

The Main Types of Neurotechnology Being Studied for SCI

Six approaches account for the SCI results in the published record: intracortical brain implants, the neural bypass, brain-spine interfaces, epidural spinal cord stimulation, transcutaneous spinal cord stimulation, and endovascular or surface arrays that avoid open-brain surgery, with functional electrical stimulation (FES) as the older technology several of them build on [20][25]. Five of the six are investigational in the United States. One transcutaneous system has FDA marketing authorization for a narrow indication [1]. Each subsection below ends with that status, in the FDA's own words where an FDA document exists.

Intracortical Brain Implants: BrainGate, Neuralink, and Others

The BrainGate program is the largest clinical trial of an implanted BCI and the one that has lasted longest, and its record is the best evidence available on what living with an intracortical array is like. Between 2004 and 2021, fourteen adults with tetraparesis from spinal cord injury, brainstem stroke, or motor neuron disease were enrolled through seven US clinical sites [17]. The average implant lasted 872 days, for a combined 12,203 days of safety experience. There were sixty-eight device-related adverse events, six of them serious. The most common was skin irritation around the pedestal, the connector that passes through the scalp. No event required removal of a device for safety, there were no intracranial infections, and no participant died or was left with permanently increased disability because of the device [17]. Rubin and colleagues concluded that the safety record is comparable to other chronically implanted medical devices, and they rated their own evidence Class IV, naming the lack of a control group as the study's main limitation [17].

The results across those years trace the arc described earlier. A cursor and a prosthetic hand in 2006 [5]. A robotic arm and a bottle of coffee in 2012, for two participants paralyzed by brainstem stroke rather than SCI [10]. Then, in a study that began with an implant on December 1, 2014, a 53-year-old man with a C4 complete injury received two arrays in the hand area of his motor cortex and, months later, thirty-six implanted electrodes in his right arm and shoulder. Bolu Ajiboye, Robert Kirsch, and the Case Western and Cleveland VA team linked the two, and he reached for a mug of coffee and drank from it, eleven times out of twelve in one session, 463 days after the implant. He also fed himself [20]. The authors described it as, to their knowledge, the first report of a combined implanted FES and intracortical BCI system restoring both reaching and grasping in a person with chronic tetraplegia from SCI, and it used a motorized support to carry the weight of his arm [20]. The BrainGate2 feasibility study that produced these results is still enrolling; its registry record shows a start date of May 2009 and an estimated twenty-seven participants [28].

The companies came later. Neuralink sponsors the PRIME study in the United States, registered as recruiting since January 2024 with an estimated fifteen participants, plus sibling studies in Canada, the United Arab Emirates, and the United Kingdom and a communication study called VOICE [28]. The conditions listed include cervical spinal cord injury and ALS. As of September 19, 2026, a PubMed search for this article found no peer-reviewed publication of Neuralink's clinical results, and none of its registry records links to one [28]. Blackrock Neurotech, a Salt Lake City company whose MoveAgain system pairs an implanted array with wireless control of a cursor, keyboard, wheelchair, or prosthetic, announced FDA Breakthrough Device designation for its MoveAgain system in November 2021 and a commercialization goal of 2022 [29]; no FDA clearance or approval of the system had been found as of September 19, 2026. Paradromics received FDA approval of an investigational device exemption in November 2025 to begin an early feasibility study of its Connexus implant, which passes signals from cortical microelectrodes to a receiver in the chest, and its registry record lists an estimated enrollment of two [30][28].

Status: investigational, all of them. BrainGate is a feasibility study under an investigational device exemption. Neuralink, Paradromics, and Blackrock have no cleared or approved BCI for paralysis. A Breakthrough Device designation, which two of these companies hold, is a review-program status that gives a company priority interaction with the FDA. It is not a clearance, and it does not put a device on the market [31][29].

Brain computer interface history for spinal cord injury: 1998 to 2026

Each entry is a published result, a regulatory action, or a registry status, dated to the source. Each entry is tagged by the type of technology.

  • BCIBrain-computer interface
  • Spinal cord stimulation
  • Regulatory and registry
  1. 1998 BCIFirst clinical trials of implanted brain-computer interfaces begin, the start of a 25-year record that reaches 28 trials and 67 participants by 2023 [2].
  2. 2004 BCIFirst BrainGate implant. Through 2021, the BrainGate trials will enroll 14 people through seven US sites [17].
  3. 2006 BCIHochberg and colleagues report a neural cursor and prosthetic hand control in a man three years after cervical SCI [5].
  4. 2011 Spinal cord stimulationLouisville: first reported case of standing and voluntary leg movement with stimulation on in chronic motor complete paraplegia [27].
  5. 2012 BCITwo BrainGate participants, both paralyzed by brainstem stroke, control a robotic arm in three dimensions [10].
  6. 2014 BCIApril: Ian Burkhart receives a 96-electrode array at Ohio State. June: he closes his hand around a spoon and opens it again by intention alone [16].
  7. 2016 BCIBouton and colleagues publish the neural bypass in Nature [15].
  8. 2017 BCICase Western: BCI plus implanted FES lets a man with C4 SCI reach, drink, and feed himself [20].
  9. 2018 Spinal cord stimulationLouisville reports over-ground walking with stimulation in two of four participants; Mayo Clinic reports independent stepping in one; EPFL reports targeted stimulation restoring leg control within a week [3][7][32].
  10. 2020 BCIThe neural bypass restores a sense of touch alongside movement [8].
  11. 2021 Regulatory and registryMay: FDA issues its guidance on implanted BCI devices for paralysis. Stentrode first-in-human results published. August: Ian Burkhart's device is removed [9][12][33].
  12. 2022 Spinal cord stimulationEPFL: activity-specific stimulation in three people with complete sensorimotor paralysis, within a single day [34].
  13. 2023 BCIThe brain-spine interface, one participant, Switzerland. BrainGate publishes its 17-year safety profile. SWITCH: Stentrode safe at 12 months in four people [13][17][35].
  14. 2024 Regulatory and registryMay: Up-LIFT trial of ARCEX, ONWARD's external spinal stimulator, published with 60 completers [36]. September: the 25-year review co-authored by Ian Burkhart [2]. December 19: FDA grants De Novo marketing authorization for ARCEX [1].
  15. 2025 Regulatory and registryApril: Precision Neuroscience announces 510(k) clearance for its surface array, 30-day use. November: Paradromics receives investigational device exemption (IDE) approval for an early feasibility study [11][30].
  16. 2026 Regulatory and registryRegistry status on September 19: BrainGate2 recruiting; Synchron COMMAND active, not recruiting; Neuralink PRIME recruiting; Paradromics Connect-One recruiting [28].

Dates from the cited papers, FDA documents, and ClinicalTrials.gov records as read on September 19, 2026.

The Neural Bypass: Linking Thought Back to a Person's Own Muscles

In April 2016, Chad Bouton and colleagues at Battelle Memorial Institute and The Ohio State University reported in Nature that a study participant with tetraplegia from a cervical spinal cord injury had used a chronically implanted intracortical array to control activation of his own forearm muscles through a custom stimulation system built into a sleeve [15]. The system produced isolated finger movements, and the participant gained continuous control of six wrist and hand motions. With the system on, his motor impairment on clinical assessment improved from the C5-C6 level to the C7-T1 level on that side, which gave him the ability to grasp, manipulate, and release objects [15]. The paper called the approach an electronic neural bypass [15], and the participant, though the paper does not name him, was Ian Burkhart [19][37].

The neural bypass is the one BCI in this article whose effector is the person's own hand. The wire goes from the switch straight back to the original lamp. Two later papers from the same team show how far that went. In a 2017 report, Friedenberg and colleagues showed that the participant had graded control, meaning he could produce wrist flexion at strengths in between the levels he had trained on, and described it as the first evidence in a person of volitional, graded control of muscle contraction in a paralyzed limb through a BCI [38]. A 2018 report showed he could control up to seven distinct functional hand movements, each with better than 95 percent accuracy, and improved on the Grasp and Release Test, with more transfers for every object except the block and faster transfers of the heaviest objects [14]. In 2020, Ganzer and colleagues reported in Cell that the same array could pick up the faint touch signals still arriving from his hand. A separate decoder turned those signals into vibration on his upper arm, which almost fully restored his ability to detect that he was touching an object at the same time the system moved his hand [8].

Every one of those results comes from a single participant [37], and the study that produced them lasted from 2014 to 2021 [39]. The full account of what those years were like, from the person who lived them, is in the second half of this article.

Status: investigational. The Battelle system was a research device throughout, registered on ClinicalTrials.gov as NCT01997125 [8], and its trial ended in 2021 [39].

Brain-Spine Interfaces: The "Digital Bridge"

The neural bypass ends at muscle. The brain-spine interface ends at the spinal cord, and that change of destination is the whole idea. Below an injury, the lumbosacral cord still holds the circuits that produce leg movement, and epidural stimulation can wake them up, as the next section describes. What stimulation alone cannot do is know what the person intends. A brain-spine interface adds that. Cortical signals, decoded in real time, adjust the epidural stimulation so the spinal circuits receive a command that follows the person's intent rather than a fixed program [13].

In May 2023, Henri Lorach, Grégoire Courtine, Jocelyne Bloch, and colleagues at the Swiss Federal Institute of Technology (EPFL) and Lausanne University Hospital (CHUV), working with Guillaume Charvet's team at Clinatec in Grenoble, France, which built the brain implants, reported in Nature the first such system in a person [13]. The participant, a 38-year-old man, had chronic tetraplegia from an incomplete C5/C6 injury ten years earlier. He already had a spinal stimulator from an earlier Swiss trial, and the team added two implants over the brain that linked his cortical signals to epidural stimulation of the spinal cord regions that produce walking, which the authors called a digital bridge [13]. With the bridge switched on, he could stand and walk naturally in community settings, and the system could be calibrated in a few minutes and stayed reliable over a year, including during independent use at home. After a 15-week rehabilitation program with the bridge, he had regained the ability to walk with crutches over ground even when the bridge was switched off, which the authors read as evidence that remaining pathways between the brain and the cord below the injury had reorganized [13].

That result rests on two earlier Swiss studies of the stimulation half alone. In 2018, Fabien Wagner and the same group showed that spatially targeted stimulation timed to intended movement re-established control of paralyzed leg muscles within a week in people injured more than four years earlier, and that after a few months some participants regained voluntary control without stimulation [32]. In 2022, Andreas Rowald and colleagues reported that a paddle lead designed around a computational model of the cord let three people with complete sensorimotor paralysis stand, walk, cycle, swim, and control trunk movements with activity-specific stimulation programs within a single day [34]. The 2022 study had three participants, and the brain-spine interface that followed had one. Those are the participant counts behind the headlines.

The company most associated with implanted spinal stimulation for SCI is ONWARD Medical, whose ARC-IM system consists of an implantable pulse generator and lead placed near the spinal cord, operated from a tablet and a smartwatch [31]. ONWARD is a sponsor of NASCIC's SCI patient-focused drug development meeting; that relationship had no role in what this article reports.

Status: investigational. ARC-IM holds FDA Breakthrough Device designations for blood pressure and trunk control and for mobility, which the company describes as priority review and the opportunity to interact with FDA experts during premarket review [31]. The designation is not authorization to market [40]. ONWARD is enrolling a US and Canadian trial for blood pressure instability after SCI [28]. The published brain-spine interface result is one participant in Switzerland, in a feasibility study that is still under way [13]. Neither is available outside a trial.

The digital bridge: how a brain-spine interface routes intent around the injury

Cortical signals from implanted recorders travel wirelessly out through the skin to a portable processing unit, which decodes them and sends stimulation commands back, again wirelessly, to an implanted stimulator on the spinal cord below the injury. The stimulation changes moment to moment with what the person intends, and the spinal circuits below the injury do the rest.

1 2 3 4 5 6 1 Cortical implantstwo 64-electrode recordersover the sensorimotor cortex Injury at C5/C6the brain's own signalis blocked here 5 Spinal stimulatorpulse generator and16-electrode paddle leadon the lumbar cord,below the injury 6 Leg musclescontract with thedecoded intent 2 Headsetantennas pick up the signalsthrough the skin 3 Processing unitdecodes intended hip, knee,or ankle movement 4 Belt programmerrelays the commandsevery 300 milliseconds Implanted, inside the body Worn, outside the body Wireless link The injury 1 2 3 4 5 6 1 Cortical implantstwo 64-electroderecorders over thesensorimotor cortex Injury at C5/C6the brain's own signalis blocked here 5 Spinal stimulatorpulse generator and16-electrode paddlelead on the lumbarcord, below the injury 6 Leg musclescontract with thedecoded intent 2 Headsetantennas pick up the signalsthrough the skin 3 Processing unitdecodes intended hip, knee,or ankle movement 4 Belt programmerrelays the commandsevery 300 milliseconds Implanted, inside the body Worn, outside the body Wireless link The injury 1 2 3 4 5 6
  1. 1Cortical implants. Two 64-electrode recorders over the sensorimotor cortex.
  2. 2Headset. Antennas pick up the signals through the skin.
  3. 3Processing unit. Decodes intended hip, knee, or ankle movement.
  4. 4Belt programmer. Relays the commands every 300 milliseconds.
  5. 5Spinal stimulator. Pulse generator and 16-electrode paddle lead on the lumbar cord, below the injury.
  6. 6Leg muscles. Contract with the decoded intent.
  7. Injury at C5/C6. The brain's own signal is blocked here.
  • Implanted, inside the body
  • Worn, outside the body
  • Wireless link
  • The injury
  1. 1Cortical implants. Two implants, each with 64 electrodes, sit in the skull over the leg area of the sensorimotor cortex and record the signals of intended movement.
  2. 2Headset. Antennas in a headset pick up those signals wirelessly through the skin.
  3. 3Processing unit. A portable computer decodes which joint the person intends to move, the hip, knee, or ankle, and how strongly.
  4. 4Belt programmer. A programmer worn on a belt relays the stimulation commands wirelessly to the implanted pulse generator, with an update every 300 milliseconds.
  5. 5Spinal stimulator. The pulse generator drives a 16-electrode paddle lead on the lumbar spinal cord, below the injury at C5/C6.
  6. 6Leg muscles. The targeted muscles contract with the decoded intent [13].

One participant with chronic tetraplegia, in Switzerland. The bridge was calibrated in minutes, with reliability that held for a year, including independent use at home. After 15 weeks of rehabilitation with the bridge, he could walk with crutches over ground even with the bridge switched off, which the authors read as reorganized pathways between brain and cord [13].

Lorach H, Galvez A, Spagnolo V, et al. Walking naturally after spinal cord injury using a brain-spine interface. Nature. 2023 [13]. Stimulation groundwork: Wagner FB, et al. Nature. 2018 [32]; Rowald A, et al. Nat Med. 2022 [34].

Epidural Spinal Cord Stimulation for Movement, Blood Pressure, and Bladder

Epidural spinal cord stimulation places an array of electrodes on the dura, the tough membrane covering the spinal cord, and delivers continuous electrical pulses to the cord beneath it. No brain recording is involved. In the house-wiring picture, it turns up the voltage below the cut. Harkema and colleagues proposed that the circuits below the injury become excitable enough that whatever intent still trickles across the damaged segment, plus the sensory input from the body itself, is enough to produce movement [27].

The modern record begins in Louisville. In 2011, Susan Harkema and colleagues at the University of Louisville reported on a 23-year-old man with a C7-T1 injury, motor complete with some preserved sensation, who received a 16-electrode array on the dura over the L1 to S1 cord segments after 170 sessions of locomotor training had produced no voluntary movement. With stimulation on, he achieved full weight-bearing standing with assistance only for balance, and seven months after the implant he recovered voluntary control of some leg movements, but only while the stimulation was on [27]. By 2014 the group reported four participants, and voluntary leg movement occurred with stimulation in all four, including two whose injuries were classified as motor and sensory complete [6]. In 2018, Claudia Angeli and colleagues reported in the New England Journal of Medicine that after 278 sessions over 85 weeks in one case, and 81 sessions over 15 weeks in another, two of four participants achieved over-ground walking with stimulation, and all four achieved independent standing and trunk stability. One participant suffered a hip fracture during training [3]. The same year, Megan Gill and the Mayo Clinic team reported independent stepping on a treadmill and over ground with a front-wheeled walker, with trainer assistance at the hips for balance, in one participant with complete loss of leg sensation and movement after 43 weeks of training with stimulation [7].

The leg results drew the coverage. The autonomic results may matter to more people. Harkema's group identified stimulation settings that held systolic blood pressure within a normal range in four participants with cervical injuries while they sat upright, without producing any leg muscle activity [41]. April Herrity and colleagues found settings at the tail end of the same array that improved reflexive bladder emptying, first in one participant over sixteen sessions and then in four more [42]. At the University of Minnesota, David Darrow and colleagues reported that two women, five and ten years after motor and sensory complete injuries, regained volitional leg movement the first time stimulation was switched on, without a prescribed training program beforehand, and that one of them also regained cardiovascular control during tilt testing and better bowel-bladder coordination, and experienced orgasm for the first time since her injury [43]. At the University of California, Los Angeles (UCLA), Daniel Lu and colleagues tested cervical epidural stimulation in two people with tetraplegia, one with a permanent array and one with a seven-day temporary implant, and measured roughly threefold improvements in hand strength with stimulation on [44].

Read those results with their sizes attached. One participant. Four. Two. Four. Every one of them describes function with the stimulator on, and the studies that tracked function with it off found less or none [27][6]. Maxwell Boakye and the Louisville surgical team have now described twenty-five implant procedures in a single technical series, which its authors describe as the most extensive series to date while noting that the numbers are still small [45].

Status: investigational. Epidural stimulation for movement, blood pressure, or bladder function after SCI has no FDA-cleared or approved device indication. The hardware used in the Louisville series is Medtronic spinal cord stimulator hardware of the kind first designed for pain relief, which is the subject of the next section [45][34].

Spinal Cord Stimulators for Pain Are Not the Same Thing

Search for "spinal cord stimulation for paralysis" and half the results are about a different device. Spinal cord stimulators are an established treatment for chronic neuropathic pain, supported by multiple randomized controlled trials [46], and the two uses share hardware, share a name, and share almost nothing else. Because a reader with SCI may have been offered one for pain, or may read a news story about a research implant and assume it is the same thing, the differences are worth laying out in full.

A spinal cord stimulator for chronic pain is an implanted signal generator connected to one or two implanted leads, with a remote control to turn it on and off and adjust settings [47]. The FDA approved one such device, the Evoke system, through premarket approval (PMA), its review route for high-risk Class III devices [48], for chronic intractable pain of the trunk or limbs, including pain associated with failed back surgery [47]. The FDA's own summary of that device notes a trial stimulation period, and lists people who did not get effective pain relief during that trial as people who should not receive the implant [47]. The leads are placed over the dorsal columns, the sensory tracts along the back of the cord, and the field grew out of the gate-control theory of pain, in which activating the large sensory fibers in the dorsal columns closes a gate on the pain signals traveling alongside them. Researchers now describe effects in both the spinal cord and the brain that go beyond that gate [46]. Newer devices use high-frequency or burst patterns that some studies find work better than the conventional setting [46]. The purpose of a pain stimulator is to reduce a signal going up.

Epidural stimulation for SCI uses the same class of hardware for the opposite job. The purpose is to make signals going down, and the circuits that receive them, work again. The Louisville team's technical note states that all of its research participants received a 16-electrode Medtronic paddle lead with a Medtronic RestoreAdvanced or Intellis generator [45], stimulator hardware of the kind first designed for pain relief [34]. The Swiss team wrote that paddle leads designed for pain were originally built to target the dorsal column, and then designed a new lead to target the dorsal roots involved in leg and trunk movement [34]. In the SCI research, the lead is placed low, generally between the T11 and L1 vertebrae, over the lumbosacral enlargement, a position the Louisville team found could also influence bladder and blood pressure [45], rather than at the segments chosen for a person's pain [46]. The settings are chosen for a task. The Louisville group configured electrode selection, voltage, and frequency to hold blood pressure steady without moving the legs in one study [41], found a different configuration and frequency for bladder emptying in another [42], and used others for standing and stepping [27][3]. A pain stimulator is set once to a level that dulls pain. A research stimulator for SCI may carry several programs, each for a different function, and each one was found by testing.

Think of the house again. A pain stimulator is a dimmer installed on the wire that carries alarm signals up to the house from a sensor that will not stop ringing. Epidural stimulation for SCI is the same brand of dimmer installed below the cut and turned the other way, so that the lamps on the far side get enough current to respond to a faint touch on the switch. Same part from the same catalog, mounted in a different place for a different reason.

Two consequences follow for a reader. First, a pain stimulator implanted for pain is not a research device and will not restore movement or bladder function; the search results that mix the two are mixing a treatment with an experiment. Second, no spinal cord stimulator carries an FDA indication for restoring movement or autonomic function after SCI as of September 2026. In the Louisville studies, the SCI use is research use under a study protocol [45]. The Paralyzed Veterans of America publishes a clinical practice guideline on pain after SCI, and none on stimulation for function [49].

There is a version of spinal cord stimulation that needs no surgery at all, and it is the one piece of this field that has crossed from research into a cleared product.

Same hardware, opposite job: spinal cord stimulators for pain versus epidural stimulation research for SCI

The two uses share a manufacturer and a lead design. Everything else about them differs, starting with which direction of signal the device is meant to change.

Spinal cord stimulator for chronic pain

Lead over the dorsal columns. The signal it changes travels up to the brain.

Epidural stimulation research for SCI

Same class of stimulator hardware, placed over the lumbosacral segments below the injury. The circuits it changes act below the injury.

  • Implanted hardware and the signal it changes
  • The injury
Side-by-side comparison, with sources
FeatureSpinal cord stimulator for chronic painEpidural stimulation research for SCI
PurposeRelieve chronic intractable pain in the trunk or limbs [47]Restore movement, blood pressure control, or bladder function below the injury [27][41][42]
Direction of signal changedPain signals traveling up to the brain, through activation of dorsal column fibers, with effects in the spinal cord and brain [46]Motor and autonomic circuits below the injury, made excitable enough to respond to intent and sensory input [27][7]
HardwareImplanted signal generator, one or two implanted leads, remote control [47]16-electrode Medtronic paddle lead with a Medtronic RestoreAdvanced or Intellis generator, the same class of stimulator hardware first designed for pain relief [45][34]
Where the lead sitsOver the dorsal columns, the sensory tracts along the back of the cord [46]Over the lumbosacral segments, generally placed between the T11 and L1 vertebrae, including in people with cervical injuries [45][41]
How settings are chosenSet to relieve pain; a trial stimulation period comes first [47]. Newer high-frequency and burst patterns exist [46]Configured per task: electrode selection, voltage, and frequency tuned separately for blood pressure, bladder, standing, or stepping [41][42][27]
US regulatory statusPremarket approval for chronic pain, such as the Evoke Spinal Cord Stimulation (SCS) System, approved February 28, 2022 [47]No FDA indication for restoring function after SCI. Research use under study protocols [45]
Evidence baseMultiple randomized controlled trials for pain conditions such as failed back surgery syndrome [46]Case reports and small series, one to five participants each; a 25-procedure surgical series from one center [27][3][42][45]
Clinical practice guidelinePain after SCI has a Paralyzed Veterans of America (PVA) Consortium guideline [49]None exists for stimulation to restore function [49]

Sources: Sdrulla AD, et al. Pain Pract. 2018 [46]; FDA, Evoke SCS System P190002 [47]; Boakye M, et al. Surg Neurol Int. 2023 [45]; Rowald A, et al. Nat Med. 2022 [34]; Harkema SJ, et al. Front Hum Neurosci. 2018 [41]; Herrity AN, et al. Sci Rep. 2018 [42]; PVA clinical practice guidelines index [49].

Transcutaneous Spinal Cord Stimulation and the ARCEX System

Transcutaneous spinal cord stimulation delivers current to the spinal cord through electrodes on the skin over the spine, with no implant. The idea is the same as epidural stimulation, raising the excitability of the circuits below the injury, and the price of avoiding surgery is that the current has to cross skin, muscle, and bone before it reaches the cord.

The research came out of UCLA and the University of Washington. In 2015, Yury Gerasimenko and colleagues at UCLA reported that painless transcutaneous stimulation produced voluntary movement in five of five participants with motor complete paralysis of two to six years' duration. For the last four weeks of the eighteen-week study, all five also took buspirone, a drug that acts on serotonin receptors, which brought further improvement [50]. By the end, the leg movement they could produce without stimulation, measured with the legs in a gravity-neutral support, had grown on average to match what they produced with it [50]. At the University of Washington, Fatma Inanici, Chet Moritz, and colleagues turned to the hand. Their 2018 report described a 62-year-old man with a chronic incomplete C3 injury whose pinch strength, measured with stimulation on, increased two- to sevenfold after four weeks of stimulation combined with physical therapy, and whose strength gains held for more than three months after treatment stopped [51]. Their 2021 series of six participants found rapid and sustained recovery of hand and arm function, along with reduced spasticity and, in some participants, improvements in heart rate, temperature regulation, and bladder function, with gains maintained for at least three to six months beyond stimulation in all six [23].

Those results led to the largest trial in this article. The Up-LIFT study enrolled sixty-five participants at sites in the United States, Canada, the Netherlands, and the United Kingdom, and sixty completed the protocol [36][28]. Each participant did a period of rehabilitation alone, then the same rehabilitation with ARCEX stimulation over the cervical spine. Moritz and colleagues reported in Nature Medicine in 2024 that the trial met its main effectiveness endpoint: 72 percent of participants improved by more than the minimally important difference in both strength and function, with no serious adverse events related to the therapy [36]. The design was single-arm and open-label, meaning every participant received the treatment and everyone knew it, and the comparison was to each person's own earlier period of rehabilitation without stimulation [36].

On December 19, 2024, the FDA granted a De Novo request from ONWARD Medical for the ARCEX System, creating a new device category called a transcutaneous electrical spine stimulator to improve skeletal muscle strength and sensation [1]. The FDA letter is precise about what it authorized. The device is Class II, prescription only, and intended to deliver programmed transcutaneous spinal cord stimulation in conjunction with functional task practice in the clinic to improve hand sensation and strength in people between 18 and 75 years old with a chronic, non-progressive deficit from an incomplete spinal cord injury at C2 through C8 [1]. The word "approval" does not appear in the order. A De Novo grant is a marketing authorization for a device with no existing category, and it is a different thing from the premarket approval that pain stimulators go through. It is also the only FDA marketing authorization in this article for a device intended to improve function after SCI.

Two limits are worth holding onto. The indication is in-clinic use alongside functional task practice, not a device a person takes home; a home-use study was registered and completed, but no FDA document extending the indication was found for this article [1][28]. And the indication is incomplete cervical injury. People with complete injuries, or injuries below C8, are outside it. NASCIC's ARCEX hand function webinar page holds the clinical details on how the therapy is delivered. ONWARD is a sponsor of NASCIC's SCI patient-focused drug development meeting; that relationship had no role in this article.

Status: ARCEX has FDA De Novo marketing authorization for the indication above. Transcutaneous stimulation for any other purpose, including the leg, bladder, and cardiovascular findings in the research, remains investigational.

Functional Electrical Stimulation: Where It Fits

Several of the devices above are built on a technology that is decades older than any of them. Functional electrical stimulation (FES) applies electrical current to the intact nerves that supply paralyzed muscles, making them contract, and when those contractions are coordinated to produce a useful action the technique earns the word "functional" [25]. The neural bypass is a BCI driving an FES sleeve [15]. The Case Western system that let a man drink coffee was a BCI driving implanted FES electrodes [20]. Take the brain recording away and what remains is FES on its own, controlled by a switch, a sensor, or a therapist.

FES is also the one technology in this article a person is most likely to have already used. Ho and colleagues, in a 2014 review from the Cleveland FES Center and its collaborators, wrote that many FES devices are commercially available and should be considered part of lifelong rehabilitation care for every eligible person with SCI [52]. Systems for the arm, the leg, the bladder and bowel, and breathing all exist, some as products and some in research settings [25]. NASCIC's own pages on FES cover the therapy side in depth: the FES therapy webinar with Restorative Therapies and the Integrated FES podcast. This article does not repeat them.

One piece of FES history belongs here because it shapes the risk section later on. The Freehand system, a hand neuroprosthesis developed at Case Western, reached the market through a local start-up in 1997. The company that held the rights closed in 2001, no other company took the device on, and around 350 people were left with implanted hardware and no manufacturer behind it [24]. That story is the reason the question "what happens when the company or the trial ends" appears in this article twice more.

Status: mixed. Some FES products are cleared and sold; others are research systems. No single FES clearance was verified for this article, and any specific device should be checked against the FDA's device databases.

Endovascular and Less Invasive Routes: The Stentrode and Thin-Film Arrays

The last group of devices exists to avoid the one thing every intracortical array requires: opening the skull. Two approaches have reached people.

The Stentrode, developed at the University of Melbourne with the company Synchron, is a stent lined with electrodes. It is placed by neurointerventional surgery, meaning through the blood vessels with a catheter rather than through the skull, and left in the superior sagittal sinus, a large vein adjacent to the motor cortex [12]. In 2021, Thomas Oxley and colleagues reported the first two people implanted, both with ALS, who used the device at home to type, with click accuracy above 92 percent [12]. The 2023 SWITCH safety study followed four people with ALS or primary lateral sclerosis for twelve months and found no serious adverse events, no vessel blockage, and no device migration, with stable signal throughout [35]. In the United States, Synchron's COMMAND early feasibility study enrolled six participants, and its listed conditions include spinal cord injury; the study is active and no longer recruiting [28]. Three further Synchron studies opened in 2026: INTENT, an early feasibility study in the United States, and the FOCUS studies in Australia and Canada [28]. The tradeoff is the one described earlier: a stent in a vein records less than needles in the cortex, and the published results are about controlling a computer, not a limb.

Thin-film surface arrays take a middle path. Precision Neuroscience makes a flexible electrode film that lies on the surface of the brain without penetrating it. In April 2025 the company announced FDA 510(k) clearance for that array, the Layer 7 Cortical Interface, for recording, monitoring, and stimulating electrical activity on the brain's surface for up to thirty days [11]. That clearance covers the array as a temporary recording tool. The company's own site states that its brain-computer interface is an investigational device and not for sale in the United States [11].

Status: investigational for any BCI use. The Stentrode is in early-stage studies (COMMAND and INTENT are labeled early feasibility), with no pivotal trial registered as of September 2026 [28]. Precision's array clearance is for up to thirty days of use on the brain's surface (recording, monitoring, and stimulation), not for a BCI for paralysis, and was confirmed for this article on the company's announcement rather than on the FDA database [11].

Six approaches, one marketing authorization. That ratio is the honest summary of the field, and it raises the question every reader with SCI eventually asks: what, if anything, can I get now?

The main types of neurotechnology for SCI compared: where it sits, what it aims at, and its US status

Ordered from most to least invasive. Status is as of September 19, 2026, in the FDA's own terms. "Largest SCI series" is the biggest published group of participants with spinal cord injury for that approach in the sources cited in this article.

  • Implanted
  • Implanted on a surface or in a vessel
  • On the skin
  1. Intracortical brain implant

    Investigational

    Where it sits
    Electrode array in the motor cortex; cable through the scalp or wireless
    Aims to restore
    Cursor, keyboard, robotic arm, speech, or the person's own arm via FES
    Largest SCI series
    14 participants across all causes in the BrainGate safety study; single participants in the SCI arm and hand studies [17][20]
    US status
    Feasibility study (BrainGate2), IDE early feasibility (Paradromics), PRIME (Neuralink), Breakthrough designation for the MoveAgain BCI, with its NeuroPort array 510(k) cleared for temporary recording (Blackrock) [28][30][29][53]
  2. Neural bypass

    Investigational

    Where it sits
    Array in the motor cortex plus a stimulation sleeve on the forearm
    Aims to restore
    Movement and touch in the person's own hand
    Largest SCI series
    1 participant, 2014 to 2021 [15][39]
    US status
    Research system; trial concluded in 2021 [8][39]
  3. Brain-spine interface

    Investigational

    Where it sits
    Implanted brain recorders plus an implanted epidural stimulator
    Aims to restore
    Voluntary leg movement below the injury
    Largest SCI series
    1 participant, Switzerland [13]
    US status
    Feasibility study in Switzerland [13]
  4. Epidural spinal cord stimulation

    Investigational

    Where it sits
    Paddle lead on the dura over the lumbosacral or cervical cord; generator under the skin
    Aims to restore
    Leg movement, standing, blood pressure, bladder, hand strength
    Largest SCI series
    Up to 5 participants per study; 25 procedures in one surgical series [3][42][45]
    US status
    Research use of stimulator hardware first designed for pain relief; ARC-IM holds Breakthrough designation [45][34][31]
  5. Endovascular and surface arrays

    Investigational

    Where it sits
    Stent in a vein next to the motor cortex (Stentrode); thin film on the brain surface (Precision)
    Aims to restore
    Computer control and communication
    Largest SCI series
    COMMAND early feasibility, 6 participants, conditions include SCI; published results are in ALS and primary lateral sclerosis [28][35]
    US status
    Early feasibility (Synchron); array 510(k) for up to 30 days of use (recording, monitoring, stimulation), BCI investigational (Precision) [28][11]
  6. Transcutaneous spinal cord stimulation

    De Novo granted

    Where it sits
    Electrodes on the skin over the cervical spine; no implant
    Aims to restore
    Hand sensation and strength (cleared indication); leg, bladder, and autonomic findings remain research
    Largest SCI series
    60 completers, Up-LIFT [36]
    US status
    ARCEX, December 19, 2024, Class II, in-clinic, incomplete SCI C2 to C8, ages 18 to 75 [1]
  7. Functional electrical stimulation

    Mixed

    Where it sits
    Surface or implanted electrodes on peripheral nerves and muscles
    Aims to restore
    Arm, leg, bladder and bowel, and breathing function
    Largest SCI series
    Decades of use; not itemized in this article [25][52]
    US status
    Many devices commercially available; others in research [52][25]
How a person can get it today
  1. Trial concluded

    • Neural bypass
  2. Only inside a clinical trial

    • Intracortical brain implant
    • Brain-spine interface, Switzerland
    • Epidural spinal cord stimulation
    • Endovascular and surface arrays
  3. Authorized for in-clinic use

    • Transcutaneous spinal cord stimulation
  4. Many devices commercially available

    • Functional electrical stimulation

Four approaches are open only through research studies, and the neural bypass trial has concluded. ARCEX, a transcutaneous stimulator, holds the De Novo grant, for use in the clinic [1].

Largest SCI series, participants on a log scale
  • Intracortical brain implant 14 All causes, BrainGate safety study
  • Neural bypass 1
  • Brain-spine interface 1
  • Epidural spinal cord stimulation 5 Up to 5 per study; 25 procedures in one surgical series
  • Endovascular and surface arrays 6 COMMAND; conditions include SCI
  • Transcutaneous spinal cord stimulation 60 Completers, Up-LIFT
  • Functional electrical stimulation Not itemized Decades of use

The approach with the De Novo grant also has the largest SCI series, 60 people. The implanted brain and spinal cord approaches rest on 1 to 14 participants, and the 14 include causes other than SCI.

Status verified on FDA.gov, ClinicalTrials.gov, and company regulatory announcements on September 19, 2026 [1][28][31][11][29][30]. Participant counts from the cited papers.

Where the Science Is Today and What It Means for You

As of September 2026, one spinal cord stimulation or BCI device intended to improve function after spinal cord injury holds FDA marketing authorization, and it is an external stimulator used in a clinic for one indication [1]. As of the 2024 review, no implanted brain-computer interface had been approved by any regulator for the medical device market, despite clinical trials dating to 1998 [2]. Every other spinal stimulation or BCI device described in this article is available only inside a clinical trial, and most of it has been tested in fewer than five people. Those three sentences are the state of the field. The rest of this section is about what they mean for a person deciding whether to hope, to wait, or to enroll.

What Is Investigational Today and What Is Available Now

Available now, for the narrow group it covers, is ARCEX: in-clinic transcutaneous stimulation with task practice, for adults 18 to 75 with a chronic incomplete cervical injury, to improve hand sensation and strength [1]. A 2014 review listed commercial FES systems, such as surface stimulators for the hand and FES cycling, and recommended considering them for every eligible person with SCI [52]. That is the complete list.

Investigational, which means not for sale, is every implanted device in this article. The distinction matters because the vocabulary around it is slippery. A device under an investigational device exemption (IDE) is one the FDA has allowed into a clinical study; the FDA's own guidance describes feasibility and pivotal studies as IDE studies [9], and the exemption lets an investigational device be used in a clinical study to collect the data a marketing application needs, without approving the device [48]. A Breakthrough Device designation is a review-program status that gives a company priority interaction with FDA staff on the way to a future submission; ONWARD's own announcement describes it in those terms [31]. A 510(k) clearance is the route for devices substantially equivalent to one already legally on the market [48], which is what Precision Neuroscience announced for its array, cleared for up to thirty days of use on the brain's surface (recording, monitoring, and stimulation) [11]. A De Novo grant creates a new category for a novel lower-risk device, which is what ARCEX received [1]. Premarket approval (PMA) is the FDA's review route for high-risk Class III devices [48], and it is the route the Evoke pain stimulator took [47]. When a headline says a brain implant was "approved," it is worth checking which of these five terms applies. In the sources gathered for this article, every implanted BCI held an investigational device exemption or a Breakthrough Device designation, and neither one puts a device on the market.

The practical questions follow from that. A person cannot buy one. Paradromics states that the devices in its study are only available for investigational use and not for sale in any country, and Precision states that its BCI is an investigational device not available for sale in the United States [30][11]. There is no price, because there is no product for sale; the cost question that does apply, who pays when the device breaks or the trial ends, is taken up below. Neuralink is not available outside its studies. It is enrolling participants, with an estimated fifteen in the US study [28], and as of September 19, 2026, no peer-reviewed clinical results had appeared in PubMed.

How Clinical Trials Work and How to Find One

Device trials do not follow the drug-trial phases most people have heard of. The FDA's 2021 guidance on implanted BCIs for paralysis names three kinds of IDE study: an early feasibility study, to give proof of principle and initial clinical safety data; a traditional feasibility study, which may have a small number of participants; and a pivotal study, designed to show effectiveness in support of a marketing submission [9]. Nearly every study in this article sits in the first two categories. The BrainGate2 study is registered as a feasibility study that began in May 2009 and is still recruiting, with an estimated twenty-seven participants [28]. Synchron's COMMAND study and Paradromics' Connect-One are early feasibility studies with six participants enrolled and an estimated two, respectively [28]. Up-LIFT, with sixty-five enrolled, is the one trial here that was built to support a marketing submission [28], and its investigators described it as a non-significant risk trial [36].

Every one of those studies has a public record on ClinicalTrials.gov, the US registry, under a National Clinical Trial (NCT) number. A record shows the sponsor, the status (recruiting, active but not recruiting, completed), the start date, the estimated or actual enrollment, the conditions the study accepts, and the sites [28]. Two cautions. "Estimated" enrollment is a target, not a count of people enrolled. And status fields change; every registry fact in this article was read on September 19, 2026.

For someone with SCI, the registry is a blunt tool, which is why curated listings exist. NASCIC points its community to SCItrials.org, which compiles SCI trials from registries and research networks into plain-language listings that can be filtered by injury level, time since injury, location, and intervention type [54]. The federally funded Spinal Cord Injury Model Systems, whose knowledge translation center produces the factsheets cited in this article, are the other place to ask [4][55]. Participation is voluntary, and NASCIC's own listing page says what any clinician would: talk with your healthcare team before joining any study [54].

Knowing how to find a trial is one thing. Knowing what to expect from one is another, and the honest answer starts with the question people with SCI ask first.

How a device moves from a first implant to the market, and where each program sat on September 19, 2026

The FDA expects implanted BCIs to pass through early feasibility, feasibility, and pivotal studies under an investigational device exemption before a marketing submission. The programs below are placed by their registry status and published trial design, not by press coverage.

  1. 1 Early feasibility studyA very small number of people. Tests whether the device works at all and catches problems early [9].
    • Paradromics Connect-One2 participants estimated, recruiting [28][30]
    • Synchron COMMAND6 participants, active, not recruiting [28]
    • Synchron INTENT and sibling studiesopened 2026 [28]
  2. 2 Feasibility studyBuilds an understanding of the new therapy, often in a small number of participants [9].
    • BrainGate2began May 2009, 27 participants estimated, recruiting [28]
    • Neuralink PRIMEbegan January 2024, 15 participants estimated, recruiting; the registry lists its phase as Not Applicable, as is usual for device studies [28]
    • ONWARD ARC-IM blood pressure study60 participants estimated, recruiting; phase listed as Not Applicable (device study) [28]
  3. 3 Pivotal studyDesigned to produce the evidence a marketing application rests on [9].
    • Up-LIFT (ARCEX)65 enrolled, 60 completed, single-arm, open-label, published May 2024 [36][28]
    • No implanted BCI had a pivotal study registered as of September 19, 2026 [28]
  4. 4 Marketing authorizationDe Novo for a novel lower-risk device [1], 510(k) for a device substantially equivalent to one on the market, or premarket approval for high-risk devices [48].
    • ARCEXDe Novo granted December 19, 2024, in-clinic, incomplete SCI C2 to C8 [1]
    • Precision Layer 7 array510(k) announced April 2025, for up to 30 days of use (recording, monitoring, stimulation); the BCI itself remains investigational [11]
    • No implanted BCI had reached this stage as of the 2024 review [2]

Every implanted BCI program sits in the first two stages. The only device at the final stage of the ladder for SCI, ARCEX, is worn on the skin and authorized for in-clinic use.

Words you will see on a ClinicalTrials.gov record

Recruiting
currently enrolling participants
Active, not recruiting
enrollment closed, study continuing
Completed
study finished; results may or may not be published
Estimated enrollment
a target, not a count of people enrolled
Breakthrough designation
a review-program status, not authorization to market [31]

Study sequence per FDA, Implanted Brain-Computer Interface Devices for Patients with Paralysis or Amputation, guidance, May 2021 [9]. Program placements from ClinicalTrials.gov records read September 19, 2026 [28] and the cited papers and FDA documents.

Can Paralysis Be Reversed? Realistic Expectations

The Model Systems Knowledge Translation Center answers this question in its own factsheet: there is currently no cure or proven way to completely reverse paralysis caused by SCI, and there is almost always hope for at least some improvement [55]. The factsheet separates three kinds of improvement. The severity of the injury may improve. The level may improve, and many people with complete injuries regain one to two levels. And functional abilities may improve, which the factsheet defines as what a person can do with the movement they have, including what they can do with the help of adaptive devices and assistive technologies [55].

Every result in this article belongs to that third category. A brain-computer interface does not repair the spinal cord. It routes around the injury, or it stimulates the circuits below it, and most of the function it produces exists only while the device is in place and working. When the Battelle team's system was on, Ian Burkhart's hand moved; when the study ended, it did not [15][33]. When Louisville's stimulator was on, participants moved their legs; the 2011 paper is explicit that voluntary movement returned only during stimulation [27]. Some gains did last with the device off. The Swiss brain-spine participant regained some walking ability with the bridge switched off after a 15-week rehabilitation program, and the transcutaneous hand studies described above report gains that held for months [13][23]. Those gains were partial, and they come from small groups. The word "reverse" belongs to the first two categories, and no device in this article has earned it.

The scale of the evidence is the other half of a realistic expectation. The headline results in this article come from one participant (the neural bypass, the brain-spine interface, the Mayo Clinic stimulation case, the handwriting decoder), from two to four (the Louisville and Minnesota series, the UCLA hand study), and in one case from sixty (Up-LIFT). From 1998 to 2023, sixty-seven people took part in the implanted BCI trials that the review identified worldwide [2]. Fewer than 1 percent of people with traumatic SCI recover fully by hospital discharge, and the devices described here were built for the other 99 percent, which is a reason for hope and a reason for patience in equal measure [4].

Risks, Side Effects, and What Happens When a Trial Ends

The risks of implanted neurotechnology divide into the surgical, the mechanical, and the institutional, and the third is the one people are least often warned about.

The surgical and mechanical risks are best documented by BrainGate. Across fourteen participants and 12,203 implant-days, the trial recorded sixty-eight device-related adverse events, six of them serious, with skin irritation at the scalp pedestal the most common. No device had to come out for safety reasons, and there were no intracranial infections [17]. That is a good record, and it is also fourteen people in a study with no control group, which its own authors rated Class IV [17]. Elsewhere the record includes a hip fracture during epidural stimulation training [3] and, in Ian Burkhart's case, an infection at the point where the cable entered his scalp, which, after years of funding problems, ended his time with the device [33]. The Swiss brain-spine participant had one of his two brain implants removed after 167 days because of an infection under the skin, and a replacement was implanted in March 2023 [13]. In the Louisville epidural series of twenty-five people, two developed infections and one implant had to be removed, and the authors note that generators need replacing every seven to ten years [45]. Any implant carries the risks of surgery, of infection along a wire that passes through the skin, and of hardware that degrades or fails.

The institutional risk is what happens when the study ends, the funding dries up, or the company closes. Liam Drew's 2022 reporting in Nature collected the cases: Nuvectra, a pain-stimulator company with devices in at least 3,000 people, filed for bankruptcy in 2019; Second Sight laid off most of its staff in 2020 and ended support for roughly 350 people using its retinal implant; and the Freehand hand system left around 350 people carrying hardware nobody manufactured after 2001 [24]. One trial participant, NASCIC past President Jennifer French [56], speaking in an audio clip in the same feature, put it this way: if the clinical trial is over and the system breaks, "I become paralyzed all over again," and the United States has no infrastructure to support people with implanted devices once companies go out of business or trials end [24]. Lázaro-Muñoz and colleagues at Baylor College of Medicine wrote in 2018 that there are no clear guidelines for continued access to brain implants for trial participants whose symptoms improve with them [57]. By 2026, ethicists describe a scholarly consensus that researchers, funders, and organizations have obligations to give participants continued access to, and support for, implanted devices that benefit them after a trial ends, which is a consensus about what should happen, not a description of what does [58].

Some of that gap is being worked on in the open. The Implantable Brain-Computer Interface Collaborative Community (iBCI-CC), launched in 2024 with the FDA participating, has workgroups on user priorities, clinical study endpoints, clinical practice guidelines, payer interactions, interoperability standards, and neural data privacy [59]. NASCIC is one of its founding organizations, alongside patient groups and five of the BCI companies named in this article (Blackrock Neurotech, Neuralink, Paradromics, Precision Neuroscience, and Synchron), and readers should weigh that when they see the community cited here [59]. The existence of a clinical practice guidelines workgroup is itself a fact worth knowing: no such guideline exists yet for BCIs or for spinal cord stimulation for function after SCI, in the United States or elsewhere that this article could find [49][59].

Those are the risks as the record describes them. The person who knows them best is the one who lived through a trial from the first day to the last, and who now serves the community that this article was written for.

Ian Burkhart: Living the Research

In the summer of 2010, after his freshman year of college, Ian Burkhart was on vacation with friends at the Outer Banks of North Carolina. He dove into an oncoming wave, the wave drove him onto a sandbar, and the impact caused a complete C5 injury. He was 19 [16][37]. "It left me as a quadriplegic," he told MIT Technology Review in 2023. "I had a little bit of movement in my arms, but nothing in my hands" [33]. He is the past President of the North American Spinal Cord Injury Consortium [56], and for seven and a half years he was the only participant in the trial of the device described earlier in this article as the neural bypass [33][37].

About three years after his injury, he was recruited into a clinical trial called Reanimation in Tetraplegia, conducted by The Ohio State University Wexner Medical Center with Battelle Memorial Institute [16][37]. Battelle's Chad Bouton had begun working with Ohio State's Ali Rezai and Jerry Mysiw in 2012 [19]. On April 22, 2014, Burkhart had brain surgery to receive a microelectrode array, a chip about the size of a baby aspirin carrying 96 electrodes, placed by Rezai in the hand region of his left motor cortex [16][19][14]. The other half of the system was a flexible sleeve with up to 130 electrodes wrapped around his forearm, built by Battelle to stimulate the forearm muscles that move his hand and wrist [14]. Between the two sat a computer with a decoding algorithm that had to be trained on his attempts to move. He spent seven months with the research team while it collected roughly 300 hours of data to build that algorithm [19].

In June 2014, six weeks after sessions began, he closed his hand around a spoon and opened it again using only his intention to do so [16]. "When I first opened and closed my hand using the NeuroLife BCI system, it was extremely exciting," he wrote for this article. "It showed that there is hope for this type of technology to improve the lives of people with paralysis similar to mine. One of the first things I remember thinking was that many doctors had told me over the years that I would never be able to do this again, and now I was doing exactly that. I specifically remember looking back at the research team and telling them that the real work needed to begin. If this was possible, it needed to be available to the people who could benefit from it."

The results published over the next six years describe what came after. Continuous control of six wrist and hand motions, with isolated finger movement, and a clinical improvement while using the system from the C5-C6 level to the C7-T1 level on that side, with the ability to grasp, manipulate, and release objects [15]. Graded control, so that he could set the strength of a wrist movement rather than only switch it on [38]. Seven distinct functional hand movements, each above 95 percent accuracy, and better scores on a standard grasp-and-release test [14]. And in 2020, the return of a sense of touch, as the array picked up faint signals still arriving from his hand and the system relayed them as vibration on his upper arm while it moved his hand [8]. He is the first person with tetraplegia to regain functional movement in his own paralyzed hand through an implanted BCI linked to muscle stimulation [15][39].

"It worked really well," he said of the system. "We started off just being able to open and close my hand, but after some time we were able to do individual finger movements" [33]. The sleeve, the cable through his scalp, and the computer were research equipment. "There was a lot that I was able to do, which was exciting," he said. "But it was also still limited." And: "It was kind of a bummer it wasn't changing everything in my life, because I had seen how beneficial it could be" [33].

The trial was planned to last twelve to eighteen months. It was extended a year at a time, and it kept going, for seven and a half years in all. He says there were stretches when it felt like no progress was being made. "At the same time, we were doing something that had never been done before," he wrote. "We kept pushing the envelope to see what was possible with the system." "It definitely gave me a lot of hope for the future," he told MIT Technology Review [33]. Around the fifth year, the money got tight. "It was probably around the five-year mark that we started running into some issues with funding," he told the magazine. He was also clear about what he did not want: "That's not the way to handle it," he said. "It's a big risk to have the device removed, and then to put one back in right away" [33]. In 2021 an infection developed at the point where the cable entered his scalp. "That was the final nail in the coffin," he said. He agreed to have the device removed in August 2021, and he has been without it since [33]. The study lasted from 2014 to 2021 [39], and in his own account he worked on the project for eight years [37].

What he said about the removal is the most useful sentence in this article for anyone weighing a trial. "When I first had my spinal cord injury, everyone said: 'You're never going to be able to move anything from your shoulders down again,'" he told MIT Technology Review. "I was able to restore that function, and then lose it again. That was really tough." And: "I knew the device was going to have to come out at some point. But I didn't know what it was going to feel like" [33].

Five years on, he describes it this way. "Having the device removed when the study ended in 2021 was extremely difficult because it had become such a significant part of my day-to-day life. Although I knew it would eventually be removed, whether because the device stopped functioning or the trial ended, it was still a bit of a shock. Suddenly, I no longer had the option to go into the lab and move my hand again. It helped that I was only using the technology in the lab rather than in my daily life, because losing access would have been much harder if I had depended on it every day."

Asked what someone with a spinal cord injury should understand about the headlines, he is direct. "There is a lot of hype in the news about brain implants or related technologies, and it is exciting to see where the field is going. The reality is that these technologies are still part of research studies, and access is limited. It is important to understand what a device is actually capable of and to decide whether you are willing to participate in a clinical trial, rather than simply looking for the next exciting new technology."

He has spent the years since working on the problem that sentence describes. In April 2017 he established the Ian Burkhart Foundation, a 501(c)(3) nonprofit that raises funds for accessible medical equipment, advocacy, research, and financial grants to people with spinal cord injuries [16][37][60]. He founded the BCI Pioneers Coalition, which advocates for companies to be required to set up funds to support and care for volunteers when trials go wrong or end [16][33]. In 2023 he was appointed to the FDA's Patient Engagement Advisory Committee for its Center for Devices and Radiological Health [16][37]. In September 2024 he co-authored the review in Nature Reviews Bioengineering that this article has cited throughout, covering every identified clinical trial of an implanted BCI from 1998 to 2023, twenty-eight trials with sixty-seven participants, and calling for equitable enrollment, clear data ownership, and guidelines for ending device use in palliative care [2][16]. In 2025, MIT Technology Review named him to its Innovators Under 35 list [16].

At NASCIC he joined the Project Review Committee in 2018, served as Vice President and then President, and now serves as past President [16][56]. He has been a certified peer mentor with the Christopher and Dana Reeve Foundation for about a decade [16][37]. He has not stopped wanting the device back. "I definitely look forward to having another type of device implanted at some point in the future," he told MIT Technology Review in 2023 [33]. What gives him the most hope now, he wrote, "is the growing collaboration among researchers, clinicians, industry, and people with lived experience. We are seeing real progress across implanted BCIs, FES, spinal cord stimulation, and related technologies. To move these systems into daily life, we need to keep improving reliability and usability, design with end users from the beginning ... and build pathways for access, coverage, and long-term support."

Questions Worth Asking a Research Team

Ian Burkhart's own advice comes first. "Anyone considering a research study should ask about the time commitment, the risks, what support will be available, what happens when the study ends," and whether the study's goals match their own, he wrote for this article. "Research participation can be incredibly meaningful, but it is not the same as receiving a finished treatment." The record above fills in the rest of the list. None of these questions is hostile. A good research team will have answers ready, and a team that does not is telling you something.

  • How many people have used this device, and for how long? Most results in this field come from one to four participants, and a team should say so plainly [13].
  • What is the device's regulatory status, in the FDA's words? Investigational under an IDE [9], Breakthrough designation [40], 510(k), De Novo, or PMA [48][1], and which study phase this is: early feasibility, traditional feasibility, or pivotal [9].
  • What does the adverse-event record show? BrainGate publishes its safety profile; ask whether this trial's sponsor does the same [17].
  • What happens to the device when the trial ends? Who pays for maintenance, repair, or removal, and for how long, and what happens if the sponsor loses funding or closes [24][57][58].
  • What will the device do at home, as opposed to in the lab? Ian Burkhart said his system was not changing everything in his life even as it worked well in sessions [33]. The ARCEX indication is in-clinic only [1].
  • Which functions were measured, and which were reported? Studies report what they measured, and a leg-movement study may report little about the hand, bladder, or blood pressure, or the reverse [3][41][23].
  • Who else has a stake? Sponsor authorship on a paper, and any relationship between the sponsor and the organization that referred you, are fair to ask about. This article's own disclosure is in the ARCEX section.

Bring the answers to your own care team. A device trial is a medical decision, and the people who know your injury are the ones who can weigh it against your body.

Clinical disclaimer

This article is intended for educational purposes. Decisions about your own care or the care of someone you support should be made with your healthcare team, who can apply the information here to your specific situation. This content does not replace professional medical advice, diagnosis, or treatment.

References

  1. US Food and Drug Administration. De Novo Classification Order DEN240014: ARCEX System, Onward Medical Inc. December 19, 2024. 21 CFR 890.5851, product code SDO. accessdata.fda.gov.
  2. Patrick-Krueger KM, Burkhart I, Contreras-Vidal JL. The state of clinical trials of implantable brain-computer interfaces. Nat Rev Bioeng. 2025;3:50-67. Published online September 20, 2024. doi:10.1038/s44222-024-00239-5.
  3. Angeli CA, Boakye M, Morton RA, et al. Recovery of over-ground walking after chronic motor complete spinal cord injury. N Engl J Med. 2018;379(13):1244-1250. doi:10.1056/NEJMoa1803588. PMID 30247091. (University of Louisville)
  4. National Spinal Cord Injury Statistical Center. Traumatic Spinal Cord Injury Facts and Figures at a Glance, 2025 SCI Data Sheet. Birmingham, AL: University of Alabama at Birmingham; 2025. sites.uab.edu/nscisc.
  5. Hochberg LR, Serruya MD, Friehs GM, et al. Neuronal ensemble control of prosthetic devices by a human with tetraplegia. Nature. 2006;442(7099):164-171. doi:10.1038/nature04970. PMID 16838014. (Massachusetts General Hospital; Brown University)
  6. Angeli CA, Edgerton VR, Gerasimenko YP, Harkema SJ. Altering spinal cord excitability enables voluntary movements after chronic complete paralysis in humans. Brain. 2014;137(Pt 5):1394-1409. doi:10.1093/brain/awu038. PMID 24713270. (University of Louisville; UCLA)
  7. Gill ML, Grahn PJ, Calvert JS, et al. Neuromodulation of lumbosacral spinal networks enables independent stepping after complete paraplegia. Nat Med. 2018;24(11):1677-1682. doi:10.1038/s41591-018-0175-7. PMID 30250140. (Mayo Clinic; UCLA)
  8. Ganzer PD, Colachis SC 4th, Schwemmer MA, et al. Restoring the sense of touch using a sensorimotor demultiplexing neural interface. Cell. 2020;181(4):763-773.e12. doi:10.1016/j.cell.2020.03.054. PMID 32330415. (Battelle Memorial Institute; The Ohio State University)
  9. US Food and Drug Administration, Center for Devices and Radiological Health. Implanted Brain-Computer Interface (BCI) Devices for Patients with Paralysis or Amputation: Non-clinical Testing and Clinical Considerations. Guidance for Industry and Food and Drug Administration Staff. May 2021. fda.gov.
  10. Hochberg LR, Bacher D, Jarosiewicz B, et al. Reach and grasp by people with tetraplegia using a neurally controlled robotic arm. Nature. 2012;485(7398):372-375. doi:10.1038/nature11076. PMID 22596161. (BrainGate; Brown University; Department of Veterans Affairs)
  11. Precision Neuroscience Corporation. Precision Neuroscience Receives FDA Clearance for High-Resolution Cortical Electrode Array. Press release. April 17, 2025. precisionneuro.io.
  12. Oxley TJ, Yoo PE, Rind GS, et al. Motor neuroprosthesis implanted with neurointerventional surgery improves capacity for activities of daily living tasks in severe paralysis: first in-human experience. J Neurointerv Surg. 2021;13(2):102-108. doi:10.1136/neurintsurg-2020-016862. PMID 33115813. (University of Melbourne; Synchron)
  13. Lorach H, Galvez A, Spagnolo V, et al. Walking naturally after spinal cord injury using a brain-spine interface. Nature. 2023;618(7963):126-133. doi:10.1038/s41586-023-06094-5. PMID 37225984. (EPFL; Lausanne University Hospital)
  14. Colachis SC 4th, Bockbrader MA, Zhang M, et al. Dexterous control of seven functional hand movements using cortically-controlled transcutaneous muscle stimulation in a person with tetraplegia. Front Neurosci. 2018;12:208. doi:10.3389/fnins.2018.00208. PMID 29670506. (Battelle Memorial Institute; The Ohio State University)
  15. Bouton CE, Shaikhouni A, Annetta NV, et al. Restoring cortical control of functional movement in a human with quadriplegia. Nature. 2016;533(7602):247-250. doi:10.1038/nature17435. PMID 27074513. (Battelle Memorial Institute; The Ohio State University)
  16. Burkhart I. Ian's Full Story. ianburkhart.com. Accessed September 19, 2026. ianburkhart.com.
  17. Rubin DB, Ajiboye AB, Barefoot L, et al. Interim safety profile from the feasibility study of the BrainGate Neural Interface System. Neurology. 2023;100(11):e1177-e1192. doi:10.1212/WNL.0000000000201707. PMID 36639237. (Massachusetts General Hospital; BrainGate consortium)
  18. Willett FR, Avansino DT, Hochberg LR, Henderson JM, Shenoy KV. High-performance brain-to-text communication via handwriting. Nature. 2021;593(7858):249-254. doi:10.1038/s41586-021-03506-2. PMID 33981047. (Stanford University)
  19. The Ohio State University Wexner Medical Center. Neuroprosthetics Make Ian Burkhart the First Person to Move a Paralyzed Limb with the Power of Thought. Our Stories. November 16, 2015. wexnermedical.osu.edu.
  20. Ajiboye AB, Willett FR, Young DR, et al. Restoration of reaching and grasping movements through brain-controlled muscle stimulation in a person with tetraplegia: a proof-of-concept demonstration. Lancet. 2017;389(10081):1821-1830. doi:10.1016/S0140-6736(17)30601-3. PMID 28363483. (Case Western Reserve University; Cleveland FES Center)
  21. Willett FR, Kunz EM, Fan C, et al. A high-performance speech neuroprosthesis. Nature. 2023;620(7976):1031-1036. doi:10.1038/s41586-023-06377-x. PMID 37612500. (Stanford University)
  22. Card NS, Wairagkar M, Iacobacci C, et al. An accurate and rapidly calibrating speech neuroprosthesis. N Engl J Med. 2024;391(7):609-618. doi:10.1056/NEJMoa2314132. PMID 39141853. (University of California, Davis)
  23. Inanici F, Brighton LN, Samejima S, Hofstetter CP, Moritz CT. Transcutaneous spinal cord stimulation restores hand and arm function after spinal cord injury. IEEE Trans Neural Syst Rehabil Eng. 2021;29:310-319. doi:10.1109/TNSRE.2021.3049133. PMID 33400652. (University of Washington)
  24. Drew L. Abandoned: the human cost of neurotechnology failure. Nature. December 6, 2022. doi:10.1038/d41586-022-03810-5.
  25. Peckham PH, Knutson JS. Functional electrical stimulation for neuromuscular applications. Annu Rev Biomed Eng. 2005;7:327-360. doi:10.1146/annurev.bioeng.6.040803.140103. PMID 16004574. (Case Western Reserve University)
  26. Lebedev MA, Nicolelis MAL. Brain-machine interfaces: from basic science to neuroprostheses and neurorehabilitation. Physiol Rev. 2017;97(2):767-837. doi:10.1152/physrev.00027.2016. PMID 28275048. (Duke University)
  27. Harkema S, Gerasimenko Y, Hodes J, et al. Effect of epidural stimulation of the lumbosacral spinal cord on voluntary movement, standing, and assisted stepping after motor complete paraplegia: a case study. Lancet. 2011;377(9781):1938-1947. doi:10.1016/S0140-6736(11)60547-3. PMID 21601270. (University of Louisville; UCLA)
  28. ClinicalTrials.gov. Registry records NCT00912041 (BrainGate2), NCT05035823 (COMMAND), NCT03834857 (SWITCH), NCT07543367 (INTENT), NCT07533903, NCT07446114, NCT06429735 (PRIME), NCT06710626, NCT06700304, NCT06992596, NCT07127172, NCT07224256 (VOICE), NCT07357428 (Connect-One), NCT04697472 (Up-LIFT), NCT05284201 (LIFT Home), NCT07147296, NCT05941819. US National Library of Medicine. Accessed September 19, 2026. clinicaltrials.gov.
  29. Blackrock Neurotech. Blackrock Neurotech's MoveAgain Brain-Computer Interface System Receives Breakthrough Device Designation from the FDA. Press release. November 16, 2021. blackrockneurotech.com.
  30. Paradromics Inc. Paradromics Receives FDA Approval for the Connect-One Clinical Study with the Connexus Brain-Computer Interface. Press release. November 20, 2025. paradromics.com.
  31. ONWARD Medical. ONWARD Receives FDA Breakthrough Device Designation for ARC-IM for Blood Pressure and Trunk Control in Spinal Cord Injury. Press release. June 17, 2021. ir.onwd.com.
  32. Wagner FB, Mignardot JB, Le Goff-Mignardot CG, et al. Targeted neurotechnology restores walking in humans with spinal cord injury. Nature. 2018;563(7729):65-71. doi:10.1038/s41586-018-0649-2. PMID 30382197. (EPFL; Lausanne University Hospital)
  33. Hamzelou J. How it feels to have a life-changing brain implant removed. MIT Technology Review. May 26, 2023. technologyreview.com.
  34. Rowald A, Komi S, Demesmaeker R, et al. Activity-dependent spinal cord neuromodulation rapidly restores trunk and leg motor functions after complete paralysis. Nat Med. 2022;28(2):260-271. doi:10.1038/s41591-021-01663-5. PMID 35132264. (EPFL; Lausanne University Hospital)
  35. Mitchell P, Lee SCM, Yoo PE, et al. Assessment of safety of a fully implanted endovascular brain-computer interface for severe paralysis in 4 patients: the Stentrode With Thought-Controlled Digital Switch (SWITCH) study. JAMA Neurol. 2023;80(3):270-278. doi:10.1001/jamaneurol.2022.4847. PMID 36622685. (University of Melbourne; Synchron)
  36. Moritz C, Field-Fote EC, Tefertiller C, et al. Non-invasive spinal cord electrical stimulation for arm and hand function in chronic tetraplegia: a safety and efficacy trial. Nat Med. 2024;30(5):1276-1283. doi:10.1038/s41591-024-02940-9. PMID 38769431. (University of Washington; multicenter; ClinicalTrials.gov NCT04697472)
  37. Burkhart I. Biographical Sketch. Submitted for the FDA Patient Engagement Advisory Committee, 2024. Hosted at fda.gov. fda.gov/media/168235/download.
  38. Friedenberg DA, Schwemmer MA, Landgraf AJ, et al. Neuroprosthetic-enabled control of graded arm muscle contraction in a paralyzed human. Sci Rep. 2017;7(1):8386. doi:10.1038/s41598-017-08120-9. PMID 28827605. (Battelle Memorial Institute; The Ohio State University)
  39. Gent E. What it's like to live with an experimental brain implant. IEEE Spectrum. April 14, 2026. Summary reposted by Battelle Memorial Institute, May 11, 2026. battelle.org.
  40. US Food and Drug Administration. Breakthrough Devices Program. Content current as of August 31, 2026. fda.gov.
  41. Harkema SJ, Wang S, Angeli CA, et al. Normalization of blood pressure with spinal cord epidural stimulation after severe spinal cord injury. Front Hum Neurosci. 2018;12:83. doi:10.3389/fnhum.2018.00083. PMID 29568266. (University of Louisville)
  42. Herrity AN, Williams CS, Angeli CA, Harkema SJ, Hubscher CH. Lumbosacral spinal cord epidural stimulation improves voiding function after human spinal cord injury. Sci Rep. 2018;8(1):8688. doi:10.1038/s41598-018-26602-2. PMID 29875362. (University of Louisville)
  43. Darrow D, Balser D, Netoff TI, et al. Epidural spinal cord stimulation facilitates immediate restoration of dormant motor and autonomic supraspinal pathways after chronic neurologically complete spinal cord injury. J Neurotrauma. 2019;36(15):2325-2336. doi:10.1089/neu.2018.6006. PMID 30667299. (University of Minnesota)
  44. Lu DC, Edgerton VR, Modaber M, et al. Engaging cervical spinal cord networks to reenable volitional control of hand function in tetraplegic patients. Neurorehabil Neural Repair. 2016;30(10):951-962. doi:10.1177/1545968316644344. PMID 27198185. (UCLA)
  45. Boakye M, Ball T, Dietz N, et al. Spinal cord epidural stimulation for motor and autonomic function recovery after chronic spinal cord injury: a case series and technical note. Surg Neurol Int. 2023;14:87. doi:10.25259/SNI_1074_2022. PMID 37025529. (University of Louisville)
  46. Sdrulla AD, Guan Y, Raja SN. Spinal cord stimulation: clinical efficacy and potential mechanisms. Pain Pract. 2018;18(8):1048-1067. doi:10.1111/papr.12692. PMID 29526043. (Oregon Health & Science University; Johns Hopkins University)
  47. US Food and Drug Administration. Evoke Spinal Cord Stimulation (SCS) System, P190002. Recently-Approved Devices. Approval date February 28, 2022. fda.gov.
  48. US Food and Drug Administration. Overview of Device Regulation. Device Advice: Comprehensive Regulatory Assistance. Content current as of January 30, 2026. fda.gov.
  49. Paralyzed Veterans of America, Consortium for Spinal Cord Medicine. Clinical Practice Guidelines. pva.org. Updated July 28, 2026. Accessed September 19, 2026. pva.org.
  50. Gerasimenko YP, Lu DC, Modaber M, et al. Noninvasive reactivation of motor descending control after paralysis. J Neurotrauma. 2015;32(24):1968-1980. doi:10.1089/neu.2015.4008. PMID 26077679. (UCLA)
  51. Inanici F, Samejima S, Gad P, Edgerton VR, Hofstetter CP, Moritz CT. Transcutaneous electrical spinal stimulation promotes long-term recovery of upper extremity function in chronic tetraplegia. IEEE Trans Neural Syst Rehabil Eng. 2018;26(6):1272-1278. doi:10.1109/TNSRE.2018.2834339. PMID 29877852. (University of Washington; UCLA)
  52. Ho CH, Triolo RJ, Elias AL, et al. Functional electrical stimulation and spinal cord injury. Phys Med Rehabil Clin N Am. 2014;25(3):631-654. doi:10.1016/j.pmr.2014.05.001. PMID 25064792. (Cleveland FES Center; Case Western Reserve University; University of Calgary)
  53. US Food and Drug Administration. 510(k) Summary K110010: NeuroPort Electrode (SIROF), Blackrock Microsystems. Decision date February 9, 2011. Indicated for temporary (<30 days) recording and monitoring of brain electrical activity. accessdata.fda.gov.
  54. North American Spinal Cord Injury Consortium. Find SCI Clinical Trials at SCItrials.org. nascic.org. Updated September 30, 2025. nascic.org/scitrials-org.
  55. Klebine P, Smitherman O, Gernenz L, Baldessari J; Model Systems Knowledge Translation Center. Understanding Spinal Cord Injury: Part 2, Recovery and Rehabilitation. MSKTC; 2020. msktc.org.
  56. North American Spinal Cord Injury Consortium. Governance: Meet Our Leadership Team. nascic.org. Updated February 25, 2026. nascic.org/governance.
  57. Lázaro-Muñoz G, Yoshor D, Beauchamp MS, Goodman WK, McGuire AL. Continued access to investigational brain implants. Nat Rev Neurosci. 2018;19(6):317-318. doi:10.1038/s41583-018-0004-5. PMID 29686310. (Baylor College of Medicine)
  58. Bobier C, Hurst DJ. Post-trial obligations and participant enrollment in brain pioneering research: should we expand inclusion criteria? Med Health Care Philos. 2026;29(4):995-1004. doi:10.1007/s11019-026-10380-0. PMID 42435253.
  59. Implantable Brain-Computer Interface Collaborative Community. About the iBCI-CC. ibci-cc.org. Accessed September 19, 2026. ibci-cc.org.
  60. Ian Burkhart Foundation. About. ianburkhartfoundation.org. Accessed September 19, 2026. ianburkhartfoundation.org.

Uniting North American SCI Organizations

The North American SCI Consortium (NASCIC) convenes organizations across the continent that advocate, represent, and communicate with people living with spinal cord injury.

Latest Articles

Latest news, events and insights from the SCI community.